NET Series
This power connector complies with European safety standards and has also acquired UL and CSA standards.
It has a proven track record in a wide range of FA equipment, including semiconductor manufacturing equipment.
Features
RoHS | RoHS compliant |
Waterproof | none |
Locking Method | Screw locking method |
Mechanism and material features |
|
About standards |
|
Wiring Method | Soldering |
Characteristic
- Insulation resistance: When measured between the nearest conductors at the specified voltage, it is 2,000 MΩ or more.
- Withstand voltage: No short circuit or other abnormalities occur even when the specified voltage is applied between the closest conductors for one minute.
- Contact resistance: When a pair of contacts is joined to the correct length, the conductor resistance is 3 mΩ or less.
- Vibration resistance : When subjected to vibration testing, there is no functional impairment and the contact resistance is 3 mΩ or less.
- Impact: When an impact test is performed, there is no functional problem and the contact resistance is 3 mΩ or less.
- Moisture resistance: After a humidity test, there is no functional impairment and the insulation resistance is 10 MΩ or more.
- Temperature cycle: After the temperature cycle test, there is no functional problem and the insulation resistance is 2,000 MΩ or more.
- Salt spray: After conducting the salt spray test, there is no functional problem and the contact resistance is 3 mΩ or less.
Materials and Processing
Material | Process | |
Shell | Shell sizes 20 and 24: Zinc alloy Shell sizes 28 and 32: Aluminum alloy |
Matte chrome plating |
Insulator | Synthetic Resin | – |
Contact | Copper alloy | Silver plating |
Operating Temperature Limit
Shell Size | Number of Contacts | Operating Temperature Limit | Upper limit of ambient temperature when using rated current (Note) |
20 | 3 | -25℃ to +85℃ | +80℃ |
Twenty Four | 3 | -40℃~+100℃ | +70℃ |
Four | +80℃ | ||
28 | Four | +70℃ | |
8 | +93℃ | ||
32 | 3 | +70℃ | |
Four |
- (Note) Max. ambient temperature at rated current (based on TÜV certification test results)